Installation Steps for VERSA-LOK Standard, Cobble and Accent
Step 5 Install soil reinforcement (if necessary)
Versa-Grid or comparable geogrid soil reinforcement may be required on
walls in which the weight of the wall alone is not enough to resist
anticipated soil pressures.
For most walls less than 4 feet tall that have no additional loading
behind them, soil reinforcement is not necessary. For walls taller than
4 feet, or walls supporting additional loading, you should consult with
your local building officials and a licensed professional civil
engineer, if required, to determine whether soil reinforcement will be
needed. This is important, because improperly engineered walls, or walls
with insufficient soil reinforcement, could fail.
Check your geogrid manufacturers’ instructions for installation
specifications. The type, length and spacing of the geogrid will vary
for each project and should be specified in a final wall design prepared
by a licensed engineer.
Lay the geogrid on top of the units starting about 1 inch behind the
front face of the wall. Roll it out behind the wall and over the
compacted drainage aggregate and backfill. Cut to the length specified
in your construction drawings.
Position additional pieces of geogrid adjacent to one another without
overlapping. Then, place the next course of units on top of the geogrid.
Insert pins to secure the geogrid between the two courses. Remove the
slack by pulling the geogrid away from the wall face and anchoring the
back ends with stakes in each corner.
When all the geogrid sections are in place and staked tight, place
drainage aggregate and backfill and compact both.
|